YCCI-9901 Phase And Feeder Identifier

Phase and Feeder Identifier Model: YCCI-9901 Phase and Feeder Identifier is used to identify users' basic information, such as users' transformer, power and phase line etc, It serves as an effective management approach. The system adopts both pulse method and the power line carrier...
Availability:
Quantity:

Phase and Feeder Identifier


Model: YCCI-9901


Phase and Feeder Identifier is used to identify users' basic information, such as users' transformer, power and phase line etc, It serves as an effective management approach.


The system adopts both pulse method and the power line carrier signal method to identify users' information. The 2 methods can be used in combination or separately. It offers high testing accuracy, with no misjudgment or unrecognization of users occurring.


The system consists of a host testing device and handheld testing units. The host is installed on the low-voltage side of transformers, and the handheld units are used at the user side for information identification.


Features & Functions:


●  Identification functions for distinguishing the transformers and phases of the measured lines.

●  Identification of the load (the number of energy meters in use) of each phase of the transformers. 

●  Display and store the voltage value of the measured lines and measure the voltage difference 

    between the transformer side and the user side.

●  Display the odd harmonic content (of 3-51st) of the measured line, and store the total harmonics.

●  Display voltage waveform of the measured line.

●  The host device collects pulse signal from the handheld units in the method of voltage pulse 

    detection or by the current clamp to distinguish the phases and the distribution area where 

    the hanheld units are located.

●  Identify the branch line ,in which the handheld units are Located, of distribution area,by using 

    the current clamp to collect the impulse.

●  Using three current clamps, the host displays the voltage, current, angle, active power, reactive 

    power, power factor etc, while no current clamps are used ,it dispalys only voltage value with 

    the other parameters shown as zero.

●  500A and larger clamps or Rogowski coils are available for branch test.

●  Distribution area number can be freely set to distinguish the tested transformers.

●  Distinction of direction and polarity are not required for pulse test, when using handheld unit 

    connection or host's current clamp connection methods.


Specifications:


YCCI-9901 Phase and Feeder Identifier

Operating voltage:

Host: AC3 X 220v: Terminals: AC 220V

Clamp current CT or Rogowski coil(optional);

5A.500A

Frequency:

50Hz

Operating Temperature:

-10~ +45C

Host power consumption:

<2W/phase

Terminal power consumption:

<1W (when no pulse sending)

Terminal maximum pulse current:

10A;

Operating distance:

Carrier   communications: <2.7km

Pulse: >5km


Usage methods


●  The host machine


Connect the testing conductor (see 3.1) yellow ,green, red and black testing wires with UA、UB、UC、U0 terminals in the host machine respectively. The other side is connected to transformer or other power supply device by clamps. (Note: by default, yellow is phase A, green is phase B, red is phase C,and black is U0). Keep safe and follow electricity wiring rules during operation.


●  Extension


Use the plug side of power wire (see 3.2) to connect extension panel terminal and the clamp side to connect power meter (the red one is phase line and the black one is zero line). Power on after connection.


YCCI-9901_3

Guangzhou GENY Electric Co.,Ltd
ADD: Room 107,602 Guangshan 2nd road,Tianhe District, Guangzhou, 510663, China
CONTACT: John Shen
E-MAIL:
szh@geny.cn
TEL: +86-20-8703-6713 
PHONE: 008613609025617
 

Home

Leave a Message
Contact Us
Copyright @ Guangzhou GENY Electric Co.,Ltd All rights reserved.