Availability: | |
---|---|
Quantity: | |
SZ-01A-K3 Single Phase Standard Meter
● | 0.05%accuracy |
● | High performance-price ratio |
● | Testing mode:active power,reactive power |
● | Measuring voltage,current,phase angle,frequency, power factor,active power,reactive power,apparent power |
● | High stability |
● | Wide testing range |
● | Large size LCD display screen |
● | With communication port to PC |
● | The reference standard meter is accredited to conforms to EU health and safety standards with CE certificates |
Application Conditions and Requirements | |||||
Environment | Power Requirement | Safety | |||
Operation Temperature | Humidity | Altitude | Voltage Supply | IP Class | Conformity |
-10℃--+40℃ | 45%--75% | <2500m | 220V±10%,50/60Hz±2Hz | IP30 | CE conform |
Type | SZ-03A-K3 |
Test voltage | |
Range | 30V-480V |
Error | ±0.05%(30V-480V) |
Display range | 5.000000V-480.000V |
Test current | |
Range | 10mA-120A |
Error | ±0.05%(50mA-120A) ±0.1%(10mA-50mA) |
Display range | 1.000000A-120.0000A |
Power measure error | |
Active power | ±0.05%(50mA-120A) |
Reactive power | ±0.1%(50mA-120A) |
Apparent power | ±0.1%(50mA-120A) |
Phase angle | |
Range | 0°-360° |
Error | ±0.05° |
Display range | 0.01°--359.99° |
Frequency | |
Range | 45Hz-65Hz |
Display range | 45.000-65.000 |
Pulse output | |
High frequency output(CH) | 1x109(0A-1A) |
1x108 (1A-10A) | |
1x107 (10A-120A) | |
Low frequency output(CL) | 2x10-5xCH |
Pulse ratio | 1:1 |
Output level | 5V |
Pulse input | |
Input level | -- |
Input frequency | -- |
Dimensions(WxHxD)(mm) | 325x109x288 |
Weight(kg) | 5.5 |
SZ-01A-K3 Single Phase Standard Meter
● | 0.05%accuracy |
● | High performance-price ratio |
● | Testing mode:active power,reactive power |
● | Measuring voltage,current,phase angle,frequency, power factor,active power,reactive power,apparent power |
● | High stability |
● | Wide testing range |
● | Large size LCD display screen |
● | With communication port to PC |
● | The reference standard meter is accredited to conforms to EU health and safety standards with CE certificates |
Application Conditions and Requirements | |||||
Environment | Power Requirement | Safety | |||
Operation Temperature | Humidity | Altitude | Voltage Supply | IP Class | Conformity |
-10℃--+40℃ | 45%--75% | <2500m | 220V±10%,50/60Hz±2Hz | IP30 | CE conform |
Type | SZ-03A-K3 |
Test voltage | |
Range | 30V-480V |
Error | ±0.05%(30V-480V) |
Display range | 5.000000V-480.000V |
Test current | |
Range | 10mA-120A |
Error | ±0.05%(50mA-120A) ±0.1%(10mA-50mA) |
Display range | 1.000000A-120.0000A |
Power measure error | |
Active power | ±0.05%(50mA-120A) |
Reactive power | ±0.1%(50mA-120A) |
Apparent power | ±0.1%(50mA-120A) |
Phase angle | |
Range | 0°-360° |
Error | ±0.05° |
Display range | 0.01°--359.99° |
Frequency | |
Range | 45Hz-65Hz |
Display range | 45.000-65.000 |
Pulse output | |
High frequency output(CH) | 1x109(0A-1A) |
1x108 (1A-10A) | |
1x107 (10A-120A) | |
Low frequency output(CL) | 2x10-5xCH |
Pulse ratio | 1:1 |
Output level | 5V |
Pulse input | |
Input level | -- |
Input frequency | -- |
Dimensions(WxHxD)(mm) | 325x109x288 |
Weight(kg) | 5.5 |
Home | Products | News | About Us | Contact Us