YC1891D Accuracy Reference Of 0.02% Single Phase Electronic Energy Meter Test System With Two Current Channel Switching System

Established in 1987, GENY is well-known as one of the leading and professional manufacturers and suppliers of yc1891d accuracy reference of 0.02% single phase electronic energy meter test system with two current channel switching system in China. Please rest assured to buy the quality equipment...
Product description

Established in 1987, GENY is well-known as one of the leading and professional manufacturers and suppliers of yc1891d accuracy reference of 0.02% single phase electronic energy meter test system with two current channel switching system in China. Please rest assured to buy the quality equipment made in China from us and experience our good after-sale service.


 

-        Description

 

GENY’s meter test systems adopt the most advanced electronic measurement technique and modular concept combine the difference reference standards and power amplifier to meet customers’ requirements in electric power utilities, electric energy meter manufactures, measuring and quality examining departments and factories or enterprises.

 

-        Features

 

1.     The meter test system can measure mechanical meters, electronic mechanical meters and electronic meter by the way of automatic, semi-automatic or manual operation.

2.     Aluminium alloy material, light and strong and corrosion resistant.

3.     Automatic positioning rotor mark of disc of mechanical meter, with more efficiency.

4.     The swing together of the scanning heads simplifies the control.

5.     Starting test and Creeping test.

6.     Measuring different constants of meters synchronously.

7.     With the protection function of overload, short voltage circuit and open current circuit.

8.     The testing software with friendly Windows 2000/7/10 operation system, includes functional module of all kinds of modern energy meter needed, to reality error test, harmonic test, influence test etc.


 

 

Name: Electronic energy meter test bench

Model: YC1891DAT-40-0.02-F

 

 

-        Technical specification

The test bench is 40 position 0.02 accuracy single phase test system with two current channel swtiching, item No. isYC1891DAT-40-0.02-F

 

1        Power Supply

Voltage

3×240±15%

Frequency

50 Hz ±15%

Power capacity

> 6kVA

Power efficient(at full   load)

85%

Ambient temperature

-10°C -- +40°C

Relative humidity

35% -- 85%

2        Power Source

Voltage

Test voltage output   (Phase-Neutral)

30 V – 300 V

Power of the voltage   output

800VA

Resolution

Better than 0.01% of full   scale value of range

Setting accuracy

Better than 0.05% at the   final range value

Stability

Better than 0.005%/h (integration   time 150 s)

Load regulation from   0-max. load

< 0.01%

Distortion factor

< 0.3% for linear resistance   load

Harmonics

2nd – 21st   free programmable

Current

Test current output

1 mA – 120 A

Power of the current   output

1200 VA

Resolution

Better than 0.01% of full   scale value of range

Setting accuracy

Better than 0.05% at the   final range value

Stability

Better than 0.005%/h (integration   time 150 s)

Load regulation from   0-max. load

< 0.01%

Distortion factor

< 0.3% for linear   resistance load

Harmonics

2nd – 21st   free programmable

Phase angle

Range

0 -- 360°

Resolution

0.01°

Setting accuracy

0.1°

Frequency

Range

45Hz – 65Hz

Resolution

0.01Hz

3        MSVT

Number   of secondary

42

Voltage   range

300V

Ratio

1:1

Primary   to secondary ratio error

0.25%

Secondary   to secondary ratio error

0.02%

Secondary   to secondary Phase error

0.02°

Frequency   range

45Hz – 65Hz

Output   power (per winding)

15VA

4        Reference Standard Meter

SZ-01A-K3E wide-range standard meter uses the newest electric technique in the world. The core of SZ-01A-K3E is high-speed DSPCPLD and Single Chip Micyoco (SCM), it has the high-speed A/D translator with self-calibration at the same time. It can sample AC signal in high speed and deal with it in special way by DSP, this makes the circuit much simpler. It can calculate and measure AC signal exactly.

Single constant electric pulse output of SZ-01A-K3E advantages the user. It can measure voltagecurrentactive powerreactive powerapparent powerphase anglepower factorfrequency etc at the same time. It takes many kinds of balance technique and methods of data processing, in order to get the 0.02%RD of relative error.

SZ-01A-K3E has strong ability of communication. There are two communication ports on rear board—RS-232 and RS-485, they can connect PC or calibration platform respectively. Connect PC to RS-232 to calibrate the meter. Meter can realize long-distance communication through the telephone line when its RS-232 port is connected to a Modem, thus the meter can send the data to internet and realize long-distance automatic measure.

 


1.      Features

-        High accuracy

Measuring error of voltage, current, power and electric energy error ≤±0.05%

-        Wide measurement range

Voltage from 5 V to 480 V

Current from 1 mA to 120 A

-        Multi-parameter measurement

Testing single phase voltage, current, power, electric energy, power factor, phase and frequency synchronously

-        Multi-mode measurement

Single phase two wire (1P2W) active

Single phase two wire (1P2W) reactive

-        Harmonic measuring and analyze

Testing waveform distortion factor and 2nd -21st harmonic content, and displaying rod chart.

-        Verify the test bench

Measuring the asymmetry rate of voltage, current and phase in every phase and the stability of power.


 

2.      Technical specification

 

Standard   condition


Ambient   temperature

20 ℃±2

relative   humidity

60 %   ± 15 %

external   magnetic field strength

0.025 mT

Measurement   range


Rated   Current

0.001A/   0.01A / 0.1A/ 1A/ 10A/ 100A , Imax = 160A

Rated   Voltage

50V/100V/200V/400V,   Umax=480V

Measurement   Accuracy


Of current

± 0.01%RD  10mA120A 

± 0.03%RD  1mA10mA

Of Voltage

± 0.01%RD  50V400V  

± 0.05%RD  5V50V

Of Active   Power

± 0.01%RD 50V400V0.05A120A   , cosφ≥0.5

± 0.05%RD 50V400V0.001A0.05A   , cosφ≥0.5

Of Reactive   Power

± 0.01%RD  (50V400V0.05A120A   , sinφ=1.0)

± 0.01%RD  (50V400V0.05A120A   , sinφ=0.5L/0.8C)

power   factor

measurement   range: 0 ±1.000000

Accuracy:   ± 0.001%RDcosφ 0.5

Phase   angle

Measurement   range: 0 360°

Accuracy:   0.003°  (U50V,   I0.05A)

frequency

Range   : 45 65Hz

Accuracy:   ± 0.0002%RD  (U50V)

Energy   output


Input   rated voltage

57.7V/   100V/ 220V/ 380V

Inpur   rated current

0.2A   ~ 100A

Accuracy   class

Active   power:

± 0.01%RD 50V400V0.05A120A   , cosφ≥0.5

± 0.05%RD 50V400V0.001A0.05A   , cosφ≥0.5

Reactive   power:

± 0.01%RD  (50V400V0.05A120A   , sinφ=1.0)

± 0.05%RD  (50V400V0.05A120A   , sinφ=0.5L/0.8C)



Customized part:

1.      Rack

A.      In total of 40 meter position distribute on 1 meter racks, double side two rows in each side, each row include 20 positions.

B.      There is a three colour indicator light on the top of rack which neighbour to the power source cabinet.

C.      Each meter position install a GENY standard QCD (D5-4P), a push hand, a scanning head, an error display window and a DB9M socket (see following picture).

 

 

 

D.      All the current cable wiring in the rack is 35mm2

E.       Two current channel wiring and switch relay are installed in trucking on the rack

F.       DB9M socket is for RS232, RS232 is offered by MOXA C320Turbo/PCI system. MOXA system is installed under the rack.

 

2.      Cabinet

A.      Manual control device and two current channel switch are installed on the front panel of power source cabinet

 




 

B.      Two current channel switch control board is installed in the cabinet.

C.      All the current cable in cabinet are 35mm2

3.      MOXA serial port MUT communication system

  MOXA system include C320PCI-24 and Cable20PCI-32 each set, 40 ports connect with 40pcs meters

 

 


Feedback