Full-Auto Operation Single Phase Electricity Meter Test Equipment with Accuracy 0.1% ,0.05 , 0.02%

Full-Auto Operation Single Phase Electricity Meter Test Equipment with Accuracy 0.1% ,0.05 , 0.02%

Specifications: Description: The meter test system can measure mechanical meter, electronic mechanical meters and electronic meter by ways of automatic, semi-automatic or manual operation. Meters under testing: 1P2W Testing mode: active power, reactive power, cross connected reactive power With...
Product description

Single Phase Electricity Meter Test System


Brand NameGENY
Model NumberYC1891D
CertificationISO 9001
Place of OriginChina
Minimum Order Quantity1 set
Pricenegotiation
Payment TermsT/T, L/C
Supply Ability30 PCS per month
Delivery Time30 days after order confirmed
Packaging DetailsPlywood case
BrandGENY
ModelYC1891D
PowerElectric
Current loopDual- current circuit
Accuracy class0.1 , 0.05
Meter position6, 12, 24, 48, 60


Specifications:



YC1891D-6

YC1891D-12

YC1891D-24

YC1891D-48

Number of meter positions

6

12

24

48

Accuracy

0.05

Power Source

YCS-101-250

YCS-101-600

YCS-101-1200

YCS-101-2500

Standard Meter

SZ01A-K3

MSVT

HJ200GL-6

HJ200GL-12

HJ200GL-24

HJ200GL-48

QCD

D5 series

Scanning Head

YCG-2 series

Voltage

Test voltage output

24V – 288V or customized

Power of the voltage output

100VA

250VA

500VA

1000VA

Resolution

Better than 0.01% of full scale value of range

Setting accuracy

Better than 0.05% at the final range value

Stability

Better than 0.005%/h (integration time 150 s)

Load regulation from 0-max. load

Better than 0.01%

Distortion factor

Better than 0.3% for linear resistance load

Harmonics

2nd – 21st free programmable

Current

Test current output

1mA – 100A  or customized,Max.200A

1mA – 100A

Power of the current output

150VA

350VA

750VA

1500VA

Resolution

Better than 0.01% of full scale value of range

Setting accuracy

Better than 0.05% at the final range value

Stability

Better than 0.005%/h (integration time 150 s)

Load regulation from 0-max. load

Better than 0.01%

Distortion factor

Better than 0.3% for linear resistance load

Harmonics

2nd – 21st free programmable

Phase angle

Range

0 -- 360°

Resolution

0.01°

Setting accuracy

0.1°

Frequency

Range

45Hz – 65Hz

Resolution

0.01Hz

Error display

Type of error display

Red LED

Resolution of the error displays

8 digits

Voltage Supply

220V±10% or customized

50/60Hz±2Hz

3x220/380V±10% or customized

50/60Hz±2Hz

Ambient temperature

-10°C -- +40°C

Relative humidity

35% -- 85%


Description:


◇ The meter test system can measure mechanical meter, electronic mechanical meters and electronic meter by ways of automatic, semi-automatic or manual operation.

◇ Meters under testing: 1P2W

◇ Testing mode: active power, reactive power, cross connected reactive power

◇ With MSVT, can test single-phase meters with closed links between the current and voltage measuring circuits (I-P links)

◇ With current output switch, can calibrate 2 element meter(optional)

◇ Simultaneously measure meters with same specifications but different meter constants

◇ Automatic positioning rotor mark of disc of mechanical meter, with more efficiency.

◇ Starting test and creeping test

◇ With the protection function of overload, short voltage circuit and open current circuit.

◇ The swing together of the scanning heads simplifies the control.

◇ Aluminum alloy material, light and strong and corrosion resistant

◇ The testing software with friendly Windows 2000 /XP /7 /8 /10 operation system, includes functional module of all kinds of modern energy meter needed, to reality error test, harmonic test, demand test, influence test etc,. 


Primary Competitive Advantages:


◇ High quality product

◇ Over 18 months long warranty

◇ High accuracy class: 0.05

◇ 3~48 Single Phase Electric Energy Meter Test bench

◇ Extremely high power stability

◇ Neutral current test(optional)

◇ Timing error test

◇ Influence test of voltage, frequency, and harmonic

◇ Installing RS232, Ethernet communication port in each meter position.

◇ Tilt impact test (optional)


Established in 1987, GENY is well-known as one of the leading and professional manufacturers and suppliers of full-auto operation single phase electricity meter test equipment with accuracy 0.1% ,0.05 , 0.02% in China. Please rest assured to buy the quality equipment made in China from us and experience our good after-sale service.

Related Products
Feedback

Copyright © Guangzhou GENY Electric Co.,Ltd All rights reserved.Tel: +86-20-8703-6713